Name | C18 |
---|---|
Synonyms | B1; D1; BBS 9; BBS9; BBS9 GENE; Bardet Biedl syndrome 9 protein; C18; PTH responsive osteosarcoma B1 protein… |
Name | ametryn |
---|---|
CAS |
PubMed | Abstract | RScore(About this table) | |
---|---|---|---|
15065776 | Melo LF, Collins CH, Jardim IC: New materials for solid-phase extraction and multiclass high-performance liquid chromatographic analysis of pesticides in grapes. J Chromatogr A. 2004 Apr 2;1032(1-2):51-8. Sample preparation procedures which included the use of new aminopropyl (NH2) and octadecyl (C18) solid-phase extraction (SPE) sorbents are proposed for the simultaneous multiclass determination of the fungicide benomyl and of the herbicides tebuthiuron, diuron, simazine, atrazine, and ametryn in grapes, using single wavelength high-performance liquid chromatography. |
6(0,0,1,1) | Details |
15909507 | Melo LF, Collins CH, Jardim IC: High-performance liquid chromatographic determination of pesticides in tomatoes using laboratory-made NH2 and C18 solid-phase extraction materials. J Chromatogr A. 2005 May 6;1073(1-2):75-81. The SPE materials were obtained by thermal immobilization of appropriate polysiloxanes onto 40 microm surfaces and were used in sample preparation for multiresidue analysis of the following pesticides: tebuthiuron and diuron (urea herbicides), simazine, atrazine and ametryn (triazines herbicides) and benomyl (benzimidazol fungicide). |
2(0,0,0,2) | Details |
12406605 | Hamada M, Wintersteiger R: Rapid screening of triazines and quantitative determination in drinking water. J Biochem Biophys Methods. 2002 Oct-Nov;53(1-3):229-39. The method was also applied to other triazine herbicides such as ametryn, atrazine, propazine, terbuthylazine and simazine. Drinking water samples spiked with triazines were extracted using RP-C18 polar plus cartridges, and the extract could be then dansylated as a total. |
1(0,0,0,1) | Details |
16797563 | Chafer-Pericas C, Herraez-Hernandez R, Campins-Falco P: On-fibre solid-phase microextraction coupled to conventional liquid chromatography versus in-tube solid-phase microextraction coupled to capillary liquid chromatography for the screening analysis of triazines in water samples. J Chromatogr A. 2006 Sep 1;1125(2):159-71. Epub 2006 Jun 23. Atrazine, simazine, propazine, ametryn, prometryn and terbutryn were selected as model compounds. The in-tube SPME approach with a C18 packed column (35 mm x 0.5 mm I.D., 5 microm particle size) connected to a switching micro-valve provided the best sensitivity; under such configuration the LODs were between 0.025 and 0.5 microg/L. |
1(0,0,0,1) | Details |
12831194 | Queiroz SC, Melo LF, Jardim IC: Poly (methyloctadecylsiloxane) immobilized on This work presents a fast, easy and effective procedure to obtain -based C18 type sorbents for use in solid-phase extraction (SPE). samples spiked with a mixture of pesticides (benomyl, tebuthiuron, diuron, simazine, atrazine and ametryn) were extracted in the off-line mode in order to evaluate the performance of this sorbent. |
by gamma radiation for use in solid-phase extraction. J Chromatogr A. 2002 Mar 1;948(1-2):171-6.1(0,0,0,1) | Details |
10720259 | Pinto GM, Jardim IC: Use of solid-phase extraction and high-performance liquid chromatography for the determination of triazine residues in water: validation of the method. J Chromatogr A. 2000 Feb 11;869(1-2):463-9. The method involves concentration with C18 solid-phase extraction cartridges followed by high-performance liquid chromatographic analysis using a C18 column with UV detection at 230 nm, a mobile phase of -water (60:40, v/v) at pH 4.6 and a flow-rate of 0.8 ml/min. The method can be used for determination of atrazine, simazine, cyanazine and ametryn in water, within the international limits of 0.1 microg/l. |
1(0,0,0,1) | Details |