Protein Information

ID 2215
Name AG1
Synonyms AG1; DMP 1; DMP1; Dentin matrix acidic phosphoprotein; Dentin matrix acidic phosphoprotein 1; Dentin matrix acidic phosphoprotein 1 precursor; Dentin matrix protein 1; Dentin matrix acidic phosphoproteins…

Compound Information

ID 988
Name glyphosate
CAS

Reference

PubMed Abstract RScore(About this table)
15212448 Tseng SH, Lo YW, Chang PC, Chou SS, Chang HM: Simultaneous quantification of glyphosate, glufosinate, and their major metabolites in rice and soybean sprouts by gas chromatography with pulsed flame photometric detector. J Agric Food Chem. 2004 Jun 30;52(13):4057-63.
Procedures were developed for the simultaneous determination of glyphosate [N-(phosphonomethyl) glycine] and glufosinate [dl-homoalanin-4-yl-(methyl) phosphinic acid] and their major metabolites, aminomethylphosphonic acid (AMPA) and 3-(methylphosphinico) propionic acid (3-MPPA), in rice and soybean sprouts by gas chromatography (GC) equipped with a pulsed flame photometric detector (PFPD). Herbicides and their major metabolites were previously derivatized with TMOA (trimethyl orthoacetate (TMOA) in the presence of acetic acid, and their GC responses versus heating temperature (70-90 degrees C) and heating time (30-120 min) were optimized. It was found that increases in heating temperature and heating time were unfavorable for the derivatization of glyphosate or glufosinate, whereas high temperature and extended reaction time remarkably facilitated that of AMPA and 3-MPPA except at 90 degrees C for an extended reaction time (120 min). Combination of AG1-X8 anion-exchange chromatography with a Florisil cartridge cleanup process was favorable for the GC-PFPD analysis. Four types of derivatives spiked in rice and soybean sprout matrices were eluted, reaching a baseline separation, in a sequence of 3-MPPA, AMPA, glyphosate, and glufosinate within 14 min using a DB-608 capillary column. Recoveries of glyphosate, AMPA, glufosinate, and 3-MPPA (0.5 ppm) spiked in both sample matrices were determined to be 72-81, 71-86, 101-119, and 83-90%, respectively, whereas the coefficient of variation was determined to be <10% in three repeated determinations. The instrumental limits of detection for glyphosate, AMPA, glufosinate, and 3-MPPA in sample matrices were 0.02, 0.03, 0.02, and 0.01 ppm, respectively. The limits of quantification for glyphosate, AMPA, glufosinate, and 3-MPPA in sample matrices were 0.06, 0.10, 0.06, and 0.04 ppm, respectively.
1(0,0,0,1)