16201272 |
Xie D, Feng Y, Wu J, Liu S, Li X, Tao D, Gong J: Standard and quantitative analysis of cyclin E threshold by cyclin E/DNA multiparameter flow cytometry. J Huazhong Univ Sci Technolog Med Sci. 2005;25(3):282-4. The threshold of cyclin E expression at G1/S boundary is a characteristic feature of cell cycle progressing. In this study, we tried to develop a quantitative approach to analyze cyclin E threshold by multiparameter flow cytometry. The expression of cyclin E in exponentially growing MOLT-4 cells was detected under different photomultiplier tube (PMT) voltages by cyclin E/DNA multiparameter flow cytometry. Additionally, cyclin E was detected in cells which were treated with caffeine and cycloheximide (CHX) under the same PMT voltage. Moreover, the expression of cyclin E in MOLT-4 cells was compared with that in JURKAT cells. Cyclin E threshold was quantified by formula B2/AxC (A, B, C indicates the minimum, threshold, and maximum of cyclin E fluorescence intensity, respectively). Results showed that in MOLT-4 cells, cyclin E threshold calculated by formula B2/AxC was invariable under different PMT settings. It was decreased in cells treated with caffeine and remained changeless in cells treated with cycloheximide. Cyclin E threshold in JURKAT cells was much lower than that in MOLT-4 cells. It was suggested that Formula B2/AxC we firstly set up could be used to analyze cyclin E expression threshold quantitatively. |
15(0,0,1,10) |