Name | C18 |
---|---|
Synonyms | B1; D1; BBS 9; BBS9; BBS9 GENE; Bardet Biedl syndrome 9 protein; C18; PTH responsive osteosarcoma B1 protein… |
Name | imidacloprid |
---|---|
CAS |
PubMed | Abstract | RScore(About this table) | |
---|---|---|---|
18970629 | Totti S, Fernandez M, Ghini S, Pico Y, Fini F, Manes J, Girotti S: Application of matrix solid phase dispersion to the determination of imidacloprid, carbaryl, aldicarb, and their main metabolites in honeybees by liquid chromatography-mass spectrometry detection. Talanta. 2006 May 15;69(3):724-9. Epub 2005 Dec 20. A method based on matrix solid phase dispersion (MSPD) using C18 as dispersant and dichloromethane- as eluent and liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) has been developed for the simultaneous determination of imidacloprid, 6-chloronicotinic acid, carbaryl, aldicarb, aldicarb sulfoxide, and aldicarb sulfone in honeybees. |
6(0,0,1,1) | Details |
17608216 | Chen MY, Chen J, Xue J, Yu J, Cheng HZ: [Study on residue analysis method of imidacloprid in Ephedrae sinica] . Zhongguo Zhong Yao Za Zhi. 2007 Apr;32(8):675-7. METHOD: Imidacloprid was extracted with dichloromethane, cleaned up with chromatography column, then separated on Spherisorb C18 column by using -water (20:80), detected at 270 nm. |
6(0,0,1,1) | Details |
15922528 | Proenca P, Teixeira H, Castanheira F, Pinheiro J, Monsanto PV, Marques EP, Vieira DN: Two fatal intoxication cases with imidacloprid: LC/MS analysis. Forensic Sci Int. 2005 Oct 4;153(1):75-80. In the chromatographic separation, a reverse-phase column XTerra MS C18 (2.1mm i.d.x 150 mm, 5 microm) was used and the mobile phase composed with acetonitrile and 0.1% (15:85), at a 0.25 mL/min flow rate. |
1(0,0,0,1) | Details |
19916392 | Chin-Chen ML, Esteve-Romero J, Carda-Broch S: Determination of the insecticide imidacloprid in fruit juices using micellar high-performance liquid chromatography. J AOAC Int. 2009 Sep-Oct;92(5):1551-6. Samples were injected directly into a Kromasil C18 column, without any pretreatment step, using the micellar mobile phase 0.10 M and 2.5% (v/v) buffered at pH 7 and UV detection at 210 nm. |
1(0,0,0,1) | Details |
12541605 | He J, Chang JB, Guo RY, Liu P, Lin SF, Chen RF, Wang Q: [Analysis of imidacloprid and damanlin by high performance liquid chromatography]. Se Pu. 2000 Mar;18(2):181-2. It was carried out on a mu Bondapak C18 column (3.9 mm i.d. x 300 mm) with ACN-MeOH- (60:10:30, V/V) as eluent and detected at 240 nm using photodiode array detector. |
1(0,0,0,1) | Details |
15620082 | Ying GG, Kookana RS: Simultaneous determination of imidacloprid, thiacloprid, and thiamethoxam in soil and water by high-performance liquid chromatography with diode-array detection. J Environ Sci Health B. 2004;39(5-6):737-46. The soil samples were extracted with acetonitrile, while the water samples were extracted using C18 cartridges. |
1(0,0,0,1) | Details |