Protein Information

ID 24
Name muscles
Synonyms COX 7a M; COX VIIa M; COX7A; COX7A1; COX7A1 protein; COX7AH; COX7AM; Cytochrome c oxidase subunit 7a H…

Compound Information

ID 1471
Name TDE
CAS 1,1′-(2,2-dichloroethylidene)bis[4-chlorobenzene]

Reference

PubMed Abstract RScore(About this table)
10606117 Bartel T, Muller S, Nesser HJ, Mohlenkamp S, Bruch C, Erbel R: Usefulness of motion patterns indentified by tissue Doppler echocardiography for diagnosing various cardiac masses, particularly valvular vegetations. Am J Cardiol. 1999 Dec 15;84(12):1428-33.
This study sought to test whether anomalous cardiac and aortic structures can be differentiated from native tissue and artifacts by physical properties of tissue motion using transesophageal tissue Doppler echocardiography (TDE). TDE was employed in 85 consecutive patients after anomalous structures had been detected by conventional transesophageal echocardiography (TEE). The control group consisted of 40 randomized patients. Certainty of diagnosis was divided into 4 categories, and TDE signals were related to particular anomalous structures by a blinded second observer. A mechanical model of a beating ventricle was constructed and suspended in a water bath. Synthetic material was utilized to simulate anomalous intracavitary structures with varying shape, consistency, and attachment. Incoherent motion was present in endocarditic vegetations, freely oscillating thrombi, fourth-degree aortic plaques, Chiari network, valvular prolapse, tumors, and in normal valve leaflets and papillary muscles. Within 15 seconds vegetations could be detected in 17 patients (68%) using TDE versus 5 patients (20%) using only conventional imaging. Coherent motion with a phase difference occurred due to damped oscillation. This phenomenon occurred in 5 patients with thrombi of the left atrial appendage (100%), in 3 ventricular clots (75%), and in 2 hypernephroma in the right atrium (100%). Rapid identification of clots could be achieved in 15 patients (71%) versus 12 patients (57%). Concordant motion was shown in third-degree aortic plaques, postrheumatic valvular lesions, and aortic intramural hematomas, but diagnostic benefit could not be demonstrated. In 41 patients (48%) histopathologic and intraoperative results confirmed echocardiographic findings. Motion patterns could be reproduced independently of the heart rate by model experiments. This study demonstrates that TDE expedites the detection of vegetations in infective endocarditis. Diagnostic certainty can be increased as well for thrombus formations.
1(0,0,0,1)